57pao成人国产永久免费视频,国产麻花豆剧传媒精品mv在线,午夜福利电影,少妇人妻真实偷人精品视频

      <span id="8tdie"><em id="8tdie"></em></span>
    1. American Fuel Dispenser Standards

      American Fuel Dispenser Standards: Key Regulations and Specifications (English Overview)

      U.S. fuel dispenser standards are governed by federal agencies, industry bodies, and technical specifications to ensure safety, accuracy, and environmental compliance. Below is a synthesis of critical standards and their requirements:


      1. SAE ARP5904-2002**

      Title: Aviation Fueling Systems - Icing Protection for Fueling Nozzles
      Scope:

      • Applies to aviation fueling nozzles used in aircraft refueling.
        Anti-Icing Design: Nozzles must prevent ice formation at temperatures ≤-40°C.

      • Material Compatibility: Components must resist corrosion from aviation fuels (tested per ASTM D4868).

      • Pressure Testing: Withstand 3× maximum operating pressure for 10 minutes without leakage.


      2. FAA Part 23/25 - Certification Standards**

      Title: Federal Aviation Regulations (FAR) for Aircraft Fuel Systems
      Scope:

      • Mandates safety compliance for aviation fuel dispensers and tanks.
        Leakage Limits: Fuel system leakage ≤0.1 mL/min under 1.5× maximum pressure.

      • Fire Resistance: Enclosures must meet UL 94 V-0 flammability rating.

      • Electrical Safety: Wiring systems comply with UL 427 for explosion-proof installations.


      3. NIST Handbook 133**

      Title: Checking the Net Contents of Packaged Commodities
      Scope:

      • Regulates accuracy requirements for retail fuel dispensers.
        Tolerance: ±0.3% for volume measurement (±0.5% for temperature-compensated systems).

      • Repeatability: ≤0.1% error across three consecutive measurements.


      4. UL 1203 - Standard for Safety**

      Title: Explosion-Proof and Dust-Ignition-Proof Electrical Equipment
      Scope:

      • Applies to electrical components in explosive atmospheres (e.g., fueling stations).
        Enclosure Integrity: Must withstand 10 ft-lb impact without ignition.

      • Temperature Limits: Surface temperatures ≤80% of autoignition temperature of fuels.


      5. CSA C22.2 No. 22-M1986**

      Title: Electrical Equipment for Use in Hazardous Locations
      Scope:

      • Certifies explosion-proof fuel dispensers and pumps.
        Zone Classification: Compliance with Zone 1/2 requirements (intrinsically safe or flameproof).

      • Grounding: Resistance ≤10 Ω to prevent static discharge.


      6. GMW 14859-2006**

      Title: Fuel Fill Pipe and Opening - CARB Compliance
      Scope:

      • Ensures compatibility with California’s Stage II vapor recovery systems.
        Vapor Tightness: Fill pipes must limit vapor leakage to ≤15 mL during refueling.

      • Material Stability: Resists ethanol-blend fuel degradation (tested per ASTM D4868).


      7. ASME B31.3 - Process Piping**

      Title: Process Piping Design and Installation
      Scope:

      • Guides fuel transfer piping in dispensers.
        Pressure Testing: Hydrostatic pressure tests at 1.5× design pressure.

      • Corrosion Protection: Piping coatings must meet NACE MR0175 standards.


      8. EPA 40 CFR Part 60**

      Title: National Emission Standards for Hazardous Air Pollutants (NESHAP)
      Scope:

      • Limits volatile organic compound (VOC) emissions from fuel dispensers.
        Stage II Vapor Recovery: Mandatory for gasoline dispensers in ozone non-attainment areas.

      • Leak Detection: Monthly monitoring of vapor recovery systems.


      Compliance and Certification

      • FAA Certification: Required for aviation fueling systems.

      • CARB Compliance: Mandatory for dispensers in California.

      • Testing Bodies: UL, CSA, and NSF International conduct conformity assessments.


      Accessing Standards

      1. Official Sources:

        • Purchase from SAE International, FAA, or CSA Group.

      2. Third-Party Translations:


      Key Differences from Non-U.S. Standards

      AspectU.S. StandardsEU/China Standards
      Vapor RecoveryStage II mandatory in ozone zonesOptional or Stage I/II in EU
      Electrical SafetyUL/CSA focus on explosion-proofingATEX/GB/T 22380 for Zone classifications
      Accuracy Tolerance±0.3% (NIST)±0.3% (China) / ±0.5% (EU)

      For detailed implementation, refer to the full texts of SAE ARP5904, FAA FAR Part 23, and NIST Handbook 133.